1. Home
  2. /
  3. product-biorad-kr

Our Portfolio

Leverage 70+ Years of Life
Sciences Expertise

CFX Opus Real-Time PCR Systems
Choose the CFX Opus Real-Time PCR System for the reliability you depend on from Bio-Rad with improved connectivity and performance for your modern lab.
Specification

Thermal Cycler

Maximum ramp rate, °C/sec

CFX Opus 96 System: 5
CFX Opus 384 System: 2.5
CFX Opus Deepwell System: 2.5

Average ramp rate, °C/sec

CFX Opus 96 System: 3.3
CFX Opus 384 System: 2
CFX Opus Deepwell System: 2

Heating and cooling method

Peltier

Lid, °C

30–110

Temperature

Range, °C

4–100

Accuracy, °C

±0.2 of programmed target at 90°C

Uniformity, °C

CFX Opus 96 and 384 Systems:
±0.3 well-to-well after 10 sec of arrival at target
CFX Opus Deepwell System:
±0.4 well-to-well after 10 sec of arrival at target

Sample capacity, wells

96-well and 384-well versions

Dimensions (W x D x H), cm/in

33x56x36 / 13x22x14

Weight, kg/lb

22/48

Touch Screen

Adjustable from 15°–22°

Operating System

Windows 10 and up

CFX Duet Real-Time PCR System
The accuracy and consistency of Bio-Rad qPCR accessible for single and duplex experiments.
Specification

Thermal Cycler

Maximum ramp rate, °C/sec: 5

Average ramp rate, °C/sec: 3.3

Lid, °C : 30-1103.3

Temperature

Accuracy, °C : ±0.2 of programmed target at 90°C

Uniformity, °C : ±0.3 well-to-well after 10 sec of arrival at target

Gradient

Operational range, °C : 30–100

Sample capacity, wells

96-well

Dimensions (W x D x H), cm/in

33x56x36 / 13x22x14

Weight, kg/lb

22/48

Touch Screen

No Adjustable

Operating System

Windows 10 and up

PTC Tempo Thermal Cycler
Choose the PTC Tempo Thermal Cycler, which offers the thermal accuracy and uniformity you can trust to get the consistent performance you need in PCR.
Specification
General Specifications
Sample block type Fixed
Dimensions (W x D x H), cm/in 28 x 50 x 26 / 11 x 20 x 10
Power 100-240 V, 50/60 Hz, 850 W max
Electrical approvalsIEC, CE
Memory4.6GB; 100,000 files, which include protocols and run reports
Noise level 50-70 dB at steady state
Touch Screen 8 in. LCD
Programming optionsStep-based graphical and automatic
Security features for regulated environments Password protection and secure user mode
ReportingExportable run logs and system logs
Temperature control modesCalculated and block
Onboard operating systemLinux
CommunicationsWiFi, BR.io, USB A 2.0, Ethernet
Heating and cooling methodPeltier
Lid heating30–110°C
Temperature range4–100°C
Thermal accuracy+/-0.2°C of programmed target at 90°C
Thermal uniformity+/- 0.4°C well-to-well within 10 sec of arrival at 90°C

System-Specific Specifications

96-Well

Deepwell

48/48-Well

384-Well

Sample block typeAutomatedAutomatedNonautomatedAutomated
Weight15 kg (33 Ib)15 kg (33 Ib)14 kg (31 Ib)14 kg (31 Ib)
Sample capacity96 x 0.2 ml tubes or 1 x 96-well plate96 x 0.2 ml tubes, 48 x 0.5 ml tubes, or 1 x 96-well plate2 x 48 x 0.2 ml tubes or 2 x 48-well plates1 x 384-well plate
Sample nolume1-50 µl (10-50 µl recommended)1-50 µl (10-125 µl recommended)1-50 µl (10-50 µl recommended)1-30 µl (3-20 µl recommended)
Maximum ramp rate5°C/sec2.5°C/sec4°C/sec2.5°C/sec
Average ramp rate3.3°C/sec2°C/sec3°C/sec2°C/sec
(Gradient) Operational range30-100°C30-100°C30-100°C30-100°C
(Gradient) Programmable span8 rows, 1-24°C8 rows, 1-24°C8 rows, 1-24°C16 rows, 1-24°C
T100 Thermal Cycler
The 96-well T100 PCR thermal cycler offers an intuitive touch screen and reliable performance in a compact footprint.
Specification

Sample capacity

96 x 0.2 ml tubes, 0.2 ml tube strips, or 1 x 96-well plate

Maximum ramp rate, °C/sec

4

Average ramp rate, °C/sec

2.5

Temperature range

4–100°C

Temperature accuracy

±0.5°C of programmed target

Temperature uniformity

±0.5°C well-to-well within 30 sec of arrival at target temperature

Input power

100–150 VAC, 50–60 Hz; 220–240 VAC, 50–60 Hz; 700 W maximum

Display

5.7'' VGA color touch screen

Memory

500 typical programs; unlimited with USB flash drive expansion

Dimensions (W x D x H), cm/in

26 x 47 x 23 / 10 x 18 x 9

Weight, kg/lb

9/20

Gradient range

30–100°C

Temperature differential range

1–25°C